General-tools-and-instruments DAF2005MDL Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Werkzeug General-tools-and-instruments DAF2005MDL herunter. General Tools and Instruments DAF2005MDL User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - ANEMOMETER

Air velocity, Air flow, Type K/J thermometerReal time data logger, 16000 Data logger no., RS232ANEMOMETERModel : DAF2005MDL

Seite 2 - TABLE OF CONTENTS

4. GENERAL MEASURING PROCEDUREThe meter default value are following : * The air velocity unit is m/S. * The temperature unit is .℃ * The air flow

Seite 3 - 1. FEATURES

4)Hold the " Vane Probe Handle " ( 3-21, fig. 1 ) by hand& let the " Vane Probe Head " ( 3-20, Fig. 1 ) faceagainst the measu

Seite 4 - 2. SPECIFICATIONS

4)The display's bottom left side will show area size inMeter^2 ( or Ft^2 ) when make the air flowmeasurement.@ Meter^2 : Meter square, Ft^2 : Fee

Seite 5 - Anemometer sensor head :

3)Power on the meter by pressing the " Power Button "( 3-2, Fig. 1 ).4)For the Type K Probe, press the " Function Button " ( 3-6

Seite 6

b)Press the " REC Button " ( 3-4, Fig. 1 ) again, the " REC. MIN. " symbol along with the minimum valuewill appear on the display.

Seite 7 - 30 MHz only

d)Manual Data Logger ( Sampling time set to 0second ) Press the " Logger Button " ( 3-8, Fig. 1 ) once willsave the data one time into the m

Seite 8 - 3. FRONT PANEL DESCRIPTION

5. ADVANCED ADJUSTMENT PROCEDURESWhen execute the following AdvancedAdjustment Procedures should cancel the " Holdfunction " and the &quo

Seite 9

c. When make Advanced Adjustment Procedurewill use the following key buttons :ESC Button ( 3-3, Fig. 1 ), Enter Button ( 3-4, Fig. 1 ) Up Button ( 3-

Seite 10 - PROCEDURE

5-4 Sample Time Setting* Use Up Button, Down Button and Enter ( ) ▲▼ →Button to select the expect Sample Time ( HOUR-MIN.-SEC.).* After finish th

Seite 11

5-7 Air Velocity Unit Default Setting* Use Up Button, Down Button to select the▲▼default Air Velocity unit as :m/S, Ft/min, Km/h, Knots, Mile/h,*

Seite 12

TABLE OF CONTENTS1. FEATURES... 12. SPECIFICATIONS...

Seite 13 - 4-4 Data Hold

5-10 Escape from the SETTING functionPress the " ESC Button " once a while will quite andreturn to the normal measurement display.6. HOW TO

Seite 14 - 4-6 Data Logger

The meter can save 16,000 data max. , thosedata will saved into 250 memory block max. * One " Memory Block " means : The data that save int

Seite 15

3)Until the desired Memory Block no. be selected.Push the " Send Button " ( 3-7, Fig. 1 ) once, the data in the Memory Block will send out.D

Seite 16 - PROCEDURES

7. RS232 PC SERIAL INTERFACEThe instrument has RS232 PC serial interface via a 3.5mm terminal ( 3-14, Fig. 1 ).The data output is a 16 digit stream wh

Seite 17 - 5-2 Clear Memory

Each digit indicates the following status :D0 End Word = 0DD1 & D8 Display reading, D1 = LSD, D8 = MSDFor example : If the display reading is 1234

Seite 18 - 5-4 Sample Time Setting

8. BATTERY REPLACEMENT1)The time to change the UM3 ( 1.5 V ) x 4 PCsWhen the left corner of LCD display show " ", itis necessary

Seite 19

1)Slide the " Probe Lock Switch/System On/OffSwitch " from the On to Off, then On again.2)Or during the Power On, used a pin tool to pushthe

Seite 20 - FROM THE METER

Thermocouple * Measure Rage: -40 to 250 , ℃℃Probe -40 to 482 .℉℉ (Type K) TP-01 * Max. short-tern operating Temperature: 300 (572 )

Seite 21

1. FEATURES* Air velocity : m/S, Ft/min, Km/h, Knots, Mile/h,* Air flow : CMM ( m^3/min. ) and CFM ( ft^3/min. ).* Air temperature ( , )℃℉* Type K/

Seite 22

2. SPECIFICATIONS2-1 General SpecificationsCircuit Custom one-chip of microprocessor LSIcircuit.Display LCD size : 58 mm x 34 mm.MeasurementAir veloci

Seite 23 - 7. RS232 PC SERIAL INTERFACE

Temperature Automatic temp. compensation for theCompensation Type K/J thermometer.Data Hold Freeze the display reading.Memory Recall Maximum & Min

Seite 24

Optional Type K thermocouple probe.Accessories AC to DC 9V adapter.RS232 cable, UPCB-02.Data Acquisition software,SW-U801-WIN.Data Logger software, SW

Seite 25 - 9. SYSTEM RESET

Type K/J thermometerSensor Reso- Range AccuracyType lutionType K 0.1 ℃ -50.0 to 1300.0 ℃ ± ( 0.2 % + 0.5 )℃-50.1 to -100.0 ℃ ± ( 0.2 % + 1 )℃0.1

Seite 26 - 10. OPTIONAL ACCESSORIES

3. FRONT PANEL DESCRIPTION6

Seite 27 - 0501-DAF2005MDL

3-1 Display3-2 Power Button3-3 HOLD Button ( ESC Button )3-4 REC Button ( Enter Button )3-5 Up Button ▲3-6 Function Button ( Down Butt