DC Current (uA Setting, Manual Range)
Range Resolution Accuracy
0-400uA 0.1uA ±0.12% of reading ±3 digits
0-4000uA 1uA ±0.12% of reading ±3 digits
AC Current (mA Setting, Manual Range
Range Resolution Accuracy
0-40mA 0.01mA ±0.15% of reading ±5 digits
0-400mA 0.1mA ±0.15% of reading ±5 digits
DC Current (mA Setting, Manual Range)
Range Resolution Accuracy
0-40mA 0.01mA ±0.15% of reading ±5 digits
0-400mA 0.1mA ±0.15% of reading ±5 digits
Resistance (Manual Range)
Range Resolution Accuracy
0-400
Ω
0.1
Ω
±0.7% of reading ±5 digits
0-4k
Ω
0.001k
Ω
±0.6% of reading ±2 digits
0-40k
Ω
0.01k
Ω
±0.6% of reading ±2 digits
0-400k
Ω
0.1k
Ω
±0.7% of reading ±2 digits
0-4M
Ω
0.001M
Ω
±1.5% of reading ±5 digits
0-40M
Ω
0.01M
Ω
±2.0% of reading ±6 digits
Capacitance (Manual Range)
Range Resolution Accuracy
0-52nF 0.01nF ±3% of reading ±7 digits
0-520nF 0.1nF ±3% of reading ±5 digits
0-5.2uF 0.001uF ±3% of reading ±5 digits
0-52uF 0.1uF ±10% of reading ±10 digits
0-100uF 0.1uF ±10% of reading ±10 digits
Diode Integrity Check
Range Resolution Accuracy
1.5V Open 0.001V ±10% of reading ±5 digits