General-tools-and-instruments DL8829 Bedienungsanleitung Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
P
Print out the data table to either a printer or a fax /internet
application depending on available facilities.
ress icon to view detailed data table which includes 1000 sample
readings.
DATA TABLE
Click on the right mouse button anywhere over the table control to
activate a menu which contains Goto and Find menu items.
Find You can search all numeric and text cells in the entire table, or
in a selection range.
Goto You can specify a target cell to go to, using its row and column
indices.
STATISTICS
Press icon to view histograms of data based on "Whole Range" basis
or "Cursor Range" basis.
Whole Range - Sample readings which have been logged.
Cursor Range - Sample readings between two cursors.
The right part indicates Maximum,
Minimum, Mean and Standard
Deviation (Std.Dev) values from the
selected range.
Maximum
Minmium
Mean
Std.Dev
85.1
41.4
72.0
11.6
Mean:
Average value of the logged records
from selected range.
DISPLAY CONTROL
Offset - To set up from which sample reading you would like to start.
Full range of 0000 to 7500 are selectable.
Range - To set up the range of sample reading you would like to cover
in the chart. There are 50, 250, 500, 1K, 2K, 4K, 8K for
selection.
0000
2500
5000
7500
50
250
500
1K
2K
4K
8K
Authorization must be obtained from the supplier before returning.
Returned with good packing against possible damage.
The meter warrants to be free from defects in material and
workmanship for one year from the date of purchase. This warranty
covers normal operation and does not cover batteries, misuse, abuse,
alteration, tampering, neglect, improper maintenance, or damage
resulting from leaking batteries. Proof of purchase is required for
warranty repairs.
RETURN AUTHORIZATION
WARRANTY
To select a folder and name to save the data. The windows " Save
File " dialog box allows you to specify the file format to save the data,
the file name to be called and where the file to be saved to.
SAVE FILE
Std. Dev.:
Calculate each deviation between each value and Mean value; then,
get an average figure from totalism deviation.
GROUP FILES
Click on its icon to view "Multi-Logger Monitor", which is designed
to view and to compare different data files. You may select and
change the color of curve to refer to the file you retrieve by clicking
the color block. You can print the screen data by clicking the printer
icon at the right top corner.
5
6
7
The software also offers data selection function so you could set the
conditions first and then press "GO" key to highlight the database.
The selectable conditions are :
Channel: select the data type you could like to analysis.
Data Selection: AND/OR, select to decide the range selected below
is AND or OR.
Data Value: tick off and
set the needed value range.
Error: if Error code appear in
data table, when tick off this
item, the error code will be
highlighted as well.
Alarm color: pick up a color
to highlight the selected data.
Usage(Records): The software could help to count how many records
is within the range you set.
Counter ( Times): Help to count how many runs the data out of the
selected range and then come back again.
Besides the data table will be highlighted, below two information will
be counted automatically to help user doing detail analysis.
SPECIFICATION
8
2008/08/rev
o
C
1K/2K/4K/8K/12K/16K
O
F )
( - 40~185
O
- 40~85 C
SPECIFICATIONS
TEMP. RANGE
ER3 lithium battery x1
POWER BAT.
SHAPE
SAMPLE DATA
Up to 16000
SAMPLE POINTS
HOUSING
WATERPROOF
DIMENSIONS(mm)
LED SIGNAL
Red (HI,LO Alarm) /Yellow(Record)
RESOLUTION
88128
88128
RH%
8828
8829
HUMIDITY RANGE
ooo oo
++
Temp.: 0.6 C(-20~50 C) 1.2 C(-40~-20 C,51~85 C)
o
+
RH%: 3% (at 25 C,10-90%), +5% at others
BAT LOW DISPLAY
"Lo" DISPLAY
LCD DISPLAY
SIZE:12 x 25.5 mm
WATER RESISTANT
80(L)x55(W)x22(T)
0~100% RH
o
o
0.1 C (0.1 F)
ACCURACY
o
C
o
C
o
C
oo
- 30~70 C (-22~158 F)
Up to 4000
8813 8814 8815
80(L)x55(W)x22(T)
ooo oo
++
Temp.: 0.6 C(-20~50 C) , 1.2 C(-30~-20 C,51~70 C)
CR2032 x 1
"bAt" FLASH
SIZE:12 x 25.5 mm
8000
0~100%RH
Up to 8000
8833 8834 8835
Red (HI,LO Alarm) /Yellow(Record)
72(L)x56(W)x21(T)
ooo oo
++
Temp.: 0.6 C(-20~50 C) , 1.2 C(-40~-20 C,51~85 C)
o
RH% +3% at 25 C
"Battery icon" DISPLAY
SIZE:12 x 25.5 mm
15999
o
- 40~85 C (INTERNAL) ,
Red (HI,LO Alarm) /Yellow(Record)
WATERPROOF
1K/2K/4K
1K/2K/4K/8K
WATERPROOF
1K/2K/4K/8K/16K
8833
8834
o
C
8835
o
C
o
o
0.1 C (0.1 F)
o
o
0.1 C (0.1 F)
ER3 lithium battery x1
88335 88345 88355
o
- 40~100 C (EXTERNAL,8833~5)
o
10~150 C (EXTERNAL,88335~355)
1K/2K/4K/8K
Seitenansicht 1
1 2

Kommentare zu diesen Handbüchern

Keine Kommentare